How to extend the working time of 100% solids epoxy?

Up to 10% of Xylene may be used for thinning. Please follow the ratios below:

  • Up to 1 Pint of Xylene (16 oz) per 1.5-Gallon Kit

  • Up to 1 Quart of Xylene (32 oz) per 3-Gallon Kit

Do not exceed these amounts, as adding too much solvent can affect the coating’s performance, durability, and curing process. Always mix thoroughly after adding Xylene to ensure even consistency.